Craniomaxillofacial Surgery

Craniomaxillofacial Surgery

Unavailable

Code : SonicWeld Rx

Details :
  • Resorb x polymer is a 100% Poly-D,L-Lactic Acid (PDLLA).
  • Resorb xG polymer consists of 85% Poly-L-Lactic Acid (PLLA) and 15% Poly Glycolic Acid (PGA).
  • The unique ultrasound technology for insertion of resorbable SonicPins.

Craniomaxillofacial Surgery


The procedure is simple: resorbable meshes are heated up, shaped to fit the application site and then fixed in place with SonicPins inserted into predrilled holes. This is done with a sonotrode that liquefies the pins, thus causing them to bond with the meshes and penetrate into the bone cavities to anchor themselves securely.
The method is clinically certified and validated and very patient -friendly as well. The implants degrade through natural hydrolysis in a controlled process. SonicWeld Rx® is primarily stable, convenient, fast, easy and safe. Designed for cranial fixation, ideal for pediatric trauma, and indicated also for cancellous bone structures.

SonicWeld Rx®, the unique ultrasound technology for insertion of resorbable SonicPins. Watch the video to learn about the 2nd generation of SonicWeld Rx®.

SonicPins

Easiest application - maximum reliability!

Indications:

  • Osteosyntheses in non-load-bearing craniomaxillofacial areas
  • Craniofacial corrective osteotomies, for example, syndrome patients, fronto-orbital advancement in the non-load-bearing craniomaxillofacial area
  • Pediatric neurosurgery
  • Preprosthetic augmentation

Resorb x and Resorb xG implants

Maximum cleanliness and functionality for indications where it counts!

Indications:

  • Osteosyntheses in non-load-bearing craniomaxillofacial areas
  • Craniofacial corrective osteotomies, for example, syndrome patients, fronto-orbital advancement in the non-load-bearing craniomaxillofacial area
  • Pediatric neurosurgery
  • Preprosthetic augmentation

Xcelsior water bath

One

Product Informations :


  • Resorb x polymer is a 100% Poly-D,L-Lactic Acid (PDLLA).
  • Resorb xG polymer consists of 85% Poly-L-Lactic Acid (PLLA) and 15% Poly Glycolic Acid (PGA).
  • The unique ultrasound technology for insertion of resorbable SonicPins.

Related Products

About Us

B.N.M Medical, as a pioneer in Iran medical device field has been active for more than 40 years. We are one of the oldest and largest importer and supplier of medical equipment, implants, laboratory equipment and pharmaceutical in Iran and proud of our cooperation with very well-known and respected companies from all around the world.

Contact Us

  • No.9, 8th Bokharest St., Argentina Sq., Tehran1514737316
  • Tel : +98 - 21 - 88731224 -27
  • Fax: +98 - 21 -88731765